安科瑞限流式保護器 單相智能短路滅弧器
簡要描述:安科瑞限流式保護器 單相智能短路滅弧器可廣泛應(yīng)用于學(xué)校、醫(yī)院、商場、賓館、娛樂場所、寺廟、文物建筑、會展、住宅、倉庫、幼兒園、老年人建筑、集體宿舍、電動車充電站及租賃式商場商鋪、批發(fā)市場、集貿(mào)市場、甲乙丙類危險品庫房等各種用電場所末端干、支路的線路保護。
產(chǎn)品型號: ASCP200-40B
所屬分類:電氣防火限流式保護器
更新時間:2022-04-01
廠商性質(zhì):生產(chǎn)廠家
1、安科瑞限流式保護器 單相智能短路滅弧器 概述
ASCP200-1型電氣防火限流式保護器可克服傳統(tǒng)斷路器、空氣開關(guān)和監(jiān)控設(shè)備存在的短路電流大、切斷短路電流時間長、短路時產(chǎn)生的電弧火花大,以及使用壽命短等弊端,當(dāng)發(fā)生短路故障時,能以微秒級速度快速限制短路電流以實現(xiàn)滅弧保護,從而能顯著減少電氣火災(zāi)事故,保障使用場所人員和財產(chǎn)的。
ASCP200-1型電氣防火限流式保護器是單相限流式保護器,大額定電流為63A。可廣泛應(yīng)用于學(xué)校、醫(yī)院、商場、賓館、休閑場所、寺廟、會展、住宅、倉庫、電動車充電站及工廠等各種用電場所末端干、支路的線路保護。
2、安科瑞限流式保護器 單相智能短路滅弧器 功能特點
■ 短路保護功能。保護器實時監(jiān)測用電線路電流,當(dāng)線路發(fā)生短路故障時,能在150微秒內(nèi)實現(xiàn)快速限流保護,并發(fā)出聲光報警信號。
■ 過載保護功能。當(dāng)被保護線路的電流過載且過載持續(xù)時間超過動作時間(3…60秒可設(shè))時,保護器啟動限流保護,并發(fā)出聲光報警信號。
■ 表內(nèi)超溫保護功能。當(dāng)保護器內(nèi)部器件工作溫度過高時,保護器啟動超溫限流保護,并發(fā)出聲光報警信號。
■ 過、欠壓保護功能。當(dāng)保護器檢測到線路電壓過壓或欠壓時,保護器發(fā)出聲光報警信號,可預(yù)先設(shè)置是否啟動限流保護。
■ 配電線纜溫度監(jiān)測功能。當(dāng)被監(jiān)測線纜溫度超過報警設(shè)定值時,保護器發(fā)出聲光報警信號,可預(yù)先設(shè)置是否啟動限流保護。
■ 漏電流監(jiān)測功能。當(dāng)被監(jiān)測的線路漏電超過報警設(shè)定值時,保護器發(fā)出聲光報警信號,可預(yù)先設(shè)置是否啟動限流保護。
■ 保護器具有1路RS485接口,1路2G無線通訊,可以將數(shù)據(jù)發(fā)送到后臺監(jiān)控系統(tǒng),實現(xiàn)遠(yuǎn)程監(jiān)控。監(jiān)控后臺可以是安科瑞Acrel-6000/B電氣火災(zāi)監(jiān)控主機,也可以是安科瑞Acrel-6000云平臺,或第三方監(jiān)控軟件或平臺。
3、技術(shù)指標(biāo)
4、外形及安裝尺寸
5、產(chǎn)品應(yīng)用
應(yīng)用接線圖
注意事項:
1)在選用限流式保護器時,限流式保護器的設(shè)定的額定電流應(yīng)該與其前一級的斷路器的額定電流保持*。例如,當(dāng)限流式保護器輸入端斷路器的額定電流為32A時,應(yīng)將限流式保護器的額定電流設(shè)置為32A。為保障限流式保護器的正常使用,嚴(yán)禁將其使用于與其前端斷路器的額定電流不匹配的配電線路中。
2)ASCP200系列采用限流式保護器采用壁掛式安裝,可以掛墻安裝,也可以安裝在箱體內(nèi),應(yīng)確保安裝場所無滴水、腐蝕性化學(xué)氣體和沉淀物質(zhì),并注意環(huán)境溫度和通風(fēng)散熱。
3)為確??煽窟B接,接線時應(yīng)按接線圖進(jìn)行,同時為了防止接頭處接觸電阻過大而導(dǎo)致局部過熱,也避免因接觸不良而導(dǎo)致保護器工作不正常,線頭應(yīng)采用合適大小的U形冷壓頭壓接后,再插入保護器相應(yīng)端子上并將螺釘擰緊壓實。
4)保護器內(nèi)部帶有交流電,嚴(yán)禁非人士擅自打開產(chǎn)品外殼。保護器在使用期間,若被保護線路發(fā)生短路或過載故障而被限流保護時,保護器仍處于帶電狀態(tài),不允許隨意碰觸用電線路的金屬部分。待檢查線路,并排除故障后,長按保護器的復(fù)位按鍵約2秒鐘,使保護器恢復(fù)正常運行時。
5)當(dāng)保護器因超溫而發(fā)生限流保護時,則可能是因為負(fù)載電流過大,環(huán)境溫度過高或通風(fēng)散熱不良等原因?qū)е?,可通過加強通風(fēng)等措施,等保護器溫度降下來后,再長按復(fù)位鍵,使保護器復(fù)位,恢復(fù)正常運行。
1) When selecting a current-limiting protector, the rated current of the current-limiting protector should be maintained with the rated current of the circuit breaker of its predecessor*. For example, when the current limit protector input circuit breaker is rated at 32A, the current rating of the current limit protector should be set to 32A. In order to ensure the normal use of the current limit protector, it is strictly forbidden to use it in the distribution line that does not match the rated current of its front-end circuit breaker.
2) ASCP200 series using flow-limiting protector using wall mounting, can be hung wall installation, can also be installed in the box, should ensure that the installation site is free of dripping, corrosive chemical gases and precipitated substances, and pay attention to ambient temperature and ventilation and heat dissipation.
3) In order to ensure reliable connection, the wiring should be carried out according to the wiring diagram, and in order to prevent the contact resistance at the joint from being too large and causing local overheating, and also to avoid the improper operation of the protector due to poor contact, the wire head should be pressed with a U-shaped cold indenter of the appropriate size, and then inserted into the corresponding terminal of the protector and tighten the screw compaction.
4) The protector has ALTERNA inside, and it is strictly forbidden for non-persons to open the product shell without authorization. During the use of the protector, if the protected line is short-circuited or overloaded and protected by current limiting, the protector is still in a live state, and it is not allowed to touch the metal part of the power line at will. After checking the line and troubleshooting, press and hold the reset button of the protector for about 2 seconds to restore the protector to normal operation.
5) When the protector is subject to current limit protection due to overtemperature, it may be caused by excessive load current, excessive ambient temperature or poor ventilation and heat dissipation, etc. It can be caused by strengthening ventilation and other measures, and after the temperature of the protector drops, press the reset button for a long time to reset the protector and restore normal operation.
典型應(yīng)用示意圖
6、安科瑞Acrel-6000用電云平臺
安科瑞Acrelcloud-6000用電管理平臺是針對我國當(dāng)前電氣火災(zāi)事故頻發(fā)而創(chuàng)新的一套電氣火災(zāi)預(yù)警和預(yù)防管理系統(tǒng),該系統(tǒng)是基于移動互聯(lián)網(wǎng)、云計算技術(shù)、通過物聯(lián)網(wǎng)傳感終端(現(xiàn)場監(jiān)控模塊、傳輸模塊),將供電側(cè)、用電側(cè)電氣參數(shù)實時傳輸至云服務(wù)器。用電管理云平臺可以不受時間、地點、環(huán)境的限制,自行選擇合適的方式(本地電腦、手jiAPP、短信)來掌控用電系統(tǒng)的運行情況,做到“早預(yù)防、快報警、自診斷、出報告"的工作流程化。
6.1平臺結(jié)構(gòu)
6.2應(yīng)用場所
AcrelCloud-6000用電管理云平臺的主要應(yīng)用場合:
大型商場、超市、學(xué)校、養(yǎng)老院、福利院、車站、醫(yī)院、賓館等領(lǐng)域、勞動力密集型企業(yè)、易燃易爆倉庫、木材加工、紡織、涉塵、噴涂、制藥等企業(yè)、酒吧、網(wǎng)吧等娛le場所、小餐館、門店及各種小微企業(yè)。
6.3主要功能
實時監(jiān)控
24小時監(jiān)視各探測點的剩余電流、溫度、電壓、電流、狀態(tài)等信息;
歷史記錄
所有告警信息及遠(yuǎn)程控制均被記錄入日志,并可供用戶方便查詢;
數(shù)據(jù)分析
針對采集的數(shù)據(jù)進(jìn)行各種模型分析,為客戶隱患;
報警提醒
當(dāng)平臺收到報警或故障信息時,平臺將以各種方式推送和企業(yè)管理人員,提醒關(guān)注故障狀況,并采取相應(yīng)的措施隱患;
權(quán)限管理
給不同的操作人員分配不同的權(quán)限,從而提高系統(tǒng)整體性;
遠(yuǎn)程控制
具備權(quán)限的管理人員可以遠(yuǎn)程設(shè)定探測器的各種參數(shù)值,或者對監(jiān)控設(shè)備進(jìn)行分閘、合閘、復(fù)位等操作,方便管理,同時提高工作效率。
6.4平臺主要功能介紹
1)平臺首頁
通過平臺首頁可以快速瀏覽隱患巡查界面或隱患處理界面、本月隱患、故障統(tǒng)計以及項目信息地圖導(dǎo)航。
2)實時監(jiān)控
通過實時監(jiān)控界面,除了可以實時顯示項目所屬客戶、地址、建筑面積、消防設(shè)施、責(zé)任人、聯(lián)xi電話、設(shè)備數(shù)量、探測器數(shù)量等信息,還以更醒目的方式顯示了未處理報警和未處理故障信息,下屬設(shè)備和探測器,并可以查看各設(shè)備以及探測器基本信息、開關(guān)操作、數(shù)據(jù)監(jiān)控、實時數(shù)據(jù)、參數(shù)設(shè)置、歷史信息和報警信息等。
3)隱患管理
隱患管理包括隱患巡查、隱患處理、和隱患記錄。